PID Analyzers, LLC

We accept MC, VISA and AMEX
HNU - symbol for technology

PID ANALYZERS, LLC

Customer Service: 1-781-709-2131
Toll Free: 1-800-PID-6826

Instrument Quotation l Technology l Manuals l Service l MSDS l Literature
 

Portable
Analyzers

FPA Product Line
> PDF Overview
Model 102
> PID based VOC analyzer
Model 102+
> PID based VOC analyzer plus choice of sensors
Model 103
> IAQ Analyzer
Model 104
> Water quality analyzer
Model 105
> Confined Entry
Model 106
> Combustible Gas
Model 107
> Stack Gas Analyzer
Model 108
>Landfill Analyzer

Model 113
> Oxygen analyzer
Model 114
> Infrared LEL analyzer
Model 312
> Portable GC

Water
Quality
Analyzers

WQA Product Line
> PDF Overview

Con 100
> Portable Conductivity
DO 100
>Portable O2
pH 100
> pH portbale

102 DESCRIPTION
ppb mode now available!

New ppb model 102 10.6 eV PID
Utilizing the features that made the Model PI-101 the industry standard, we have revolutionized the PID. Now the PID is also a 4-gas monitor!

The model 102 PID is a single piece, hand-held unit for the measurement of organic and inorganic species that can be ionized by the UV lamp (9.5, 10.2, 10.6, 11.7).

This includes the choice of one (1) Snap-On Module (9.5, 10.2, 10.6, 11.7eV lamp), Operator's Manual, Rechargeable Nickel Metal Hydride Battery and much more...


MODEL 103 IAQ -
Indoor Air Quality Analyzer

Parameters:O2, SO2, NO, NO2, CO, CO2

High capacity electrochemical sensors and filters to eliminate interference

Fast response, datalogger, alarms, diagnostics

Light Weight: 1.5 lbs

Optional sampling system

Datalogging - 2500 site points, RS232

Applications include: Oil/coal and gas fired power plants, incinerators

102 SPECIFICATIONS

Species measured: Organics and inorganic species that can be ionized by the UV lamp (9.5, 10.2, 10.6, 11.7)

Precision: +/- 1% of reading

Response time: <1 sec. to 90% response

Span Drift:
<2% over 24 hours

Range
:
0.1 to 3000 or to 30,000 ppm with dilution probe

Linear Range
:
To 3,000 ppm direct reading

Power consumption:  < 1 watt maximum

Dimensions
:
8 " L x 3" W x 2.25" D
more...


MODEL 103 Features

PID Analyzers offers a light weight, highlyModel 103 Indoor Air Quality (IAQ) Analyzer portable Model 103 for the measurement of indoor air quality.

This robust instrument is easy to use-five button operation with LCD read out. Training non-technical users is a cinch with our intuitive software that drives the Model 103. Whether you are looking for ppm to percent levels this is the indoor quality analyzer for your monitoring needs.



Continuous
Analyzers

CMI Product Line
> PDF Overview
Model 112
> Fixed System PID
Model 201-B
> VOC Analyzer
> PID Based

Model 210

> Oxygen Monitor
Model 1000
> Toxic Gas Monitor
Model 204
> Thermal Conductivity Analyzer
Model 202
> Infrared Analyzer
Model 301-C
> Automatic GC

Water
Quality
Analyzers

WQA Product Line
> PDF Overview

Con 1000
> Controller
DO 1000
>O2 Controller
PH 1000
> pH Controller

Software

PeakWorks™
> Multi-channeled, robust GC software for any manufacturer's GC.

 

Distributors

Portables
> Authorized Dealers for PID Analyzers' Model DL-102
Continuous
> Authorized Dealers for PID Analyzers' process instruments
Europe
> Sales and service on all PID Analyzers' models in Europe

MODEL 610 SPECS

Enclosure:
Wall Mount
NEMA 4

Measurement technique
: Electrochemical sensor

Response time
: <30 sec. to 90% response;

Sample flow rate: 15-20 cc/min.-Two channel peristaltic pump (sample & reagent)

Zero drift
: <5% over 24 hours

Span drift
: <5% over 30 days

Repeatability
: 2-3 % full scale

Readout
: Digital- 5 digit bright LCD Display

Outputs Available
: 0- 1V, Digital-RS232 & 4-20 mA, (optional)

FEATURES

> Fast response < 30 seconds to 90%

> Long lifetime > 1 year for sensor

> Wide dynamic range linear from 0.1 ppm to 20

Model 610 Water Quality Analyzer

Model 610 Water Quality Analyzer

The Model 610 is a reliable, flexible and versatile analyzer based on ion selective electrodes such as: NH3, Cl-, S-2, F-, CN-, CO3-2, SO3-2.

The ion selective electrodes are potentiometric (reversible) devices that respond to achange increase as the ion is increased/decreased. The concentration is calculated via Nernst Equation:

E = E0 + [RT/nF] log [concentration] where E is the potential, E0 is a mixture of several potentials in the system, R is the gas constant, T is the absolute temperature 0K, and F is the Faraday constant.


Specifications of Water Analysis

Literature

Literature page
> Overview

CMI Product Line
> PDF Overview
FPA Product Line
> PDF Overview

WQA Product Line
> PDF Overview

 

Customer Support

Service Fast Links
Chart of Relative Sensitivities (IP)
PID Clean and Calibration Service
Online Return Authorization
Return Authorization Checklist
Model 101 FAQs
Calibration with an Alternate Gas
Calibration Gas Humidifier
Troubleshooting your 101
DL-101 Win File Transfer Instructions


Web Links
http://www.pidanalyzers.co.uk
http://www.hnunordion.fi


Industrial Hygiene



The Massachusetts Department of Health recently featured the Model PI-101 in their anti-smoking commercial proving cigarettes contain benzene.

E-mail us
for a copy.

Your home for PIDs on the Web!
PID ANALYZERS, LLC

780 CORPORATE PARK DR. PEMBROKE , MA 02359 Tel. 1-800-PID-6826, 1-781-709-2131, 1-508-660-5001 Fax 1-781-709-2050
For more info please contact us at: sales@hnu.com