PID Analyzers, LLC
Hnu I The symbol for technology
PID ANALYZERS, LLC
Model 112
 

Portable
Analyzers

All Products
> PDF Overview
Model 102
> PID based VOC analyzer
Model 102+
> PID based VOC analyzer plus choice of sensors
Model 103
> Stack gas analyzer
Model 104
> Water quality analyzer
Model 105
> Landfill gas analyzer
Model 106
> Confined entry analyzer
Model 113
> Oxygen analyzer
Model 114
> Infrared LEL analyzer
Model 312
> Portable GC
Model 71
> RH & T analyzer
Model 60
> pH, ORP, T analyzers

Software


PeakWorks™
> Multi-chanelled, robust GC software for any manufacturer's GC.

We accept MC, VISA and AMEX

FIxed System PID

Continuous
Analyzers

All Products
> PDF Overview
Model 112
> Fixed System PID
Model 201-B
> VOC Analyzer
> PID Based

Model 210

> Oxygen Monitor
Model 1000
> Toxic Gas Monitor
Model 204
> Thermal Conductivity Analyzer
Model 202
> Infrared Analyzer
Model 301-B
> Automatic GC
Model 501-B
> Process GC
Model 600
> ORP, T, dissolved oxygen in water analyzers

Distributors

Portables
> Authorized Dealers for PID Analyzers' Model DL-102
Continuous
> Authorized Dealers for PID Analyzers' process instruments
Europe
> Sales and service on all PID Analyzers' models in Europe

 

Species measured: Organics and inorganic species that can be ionized by the UV lamp (9.5, 10.2, 11.7)

Precision: 
+/- 1% of reading

Response time
:
<1 sec. to 90% response

Sample flow rate
:
> 0.2 LPM

Span
Drift:
<2% over 24 hours

Range
:
0.1 to 3000 or to 30,000 ppm with dilution probe

Linear Range
:
To 3,000 ppm direct reading


Power consumption
< 1 watt maximum

Enclosure Dimensions
:
10" L x 8" W x 4" H.

Instrument operating
conditions
5-40 degrees C, 0-95% RH (non-condensing)

Performance
: Isobutylene Referred

Model 112 Fixed PID

Model 112 Fixed System PID

PID Analyzers has developed a fixed system PID for customers who need to monitor organic and inorganic species that can be ionized with a UV lamp (9.5, 10.2, 11.7 eV).

Using PID technology, this system is tailored toward customer applications requiring low cost, high sensitivity detection methods. Based upon our portable Model 102, the Model 112 uses the same prinicpal for a fixed detection system.

Featuring a digital display and five button operation, ease of use and simplicity for training non-technical users is a cinch.

This intuitive instrument has one button calibration and installs in minutes.